Detailed Product Description
265VAC SIMV Respiratory Medical Grade Air Compressor Machine with 100% FiO2
Great Visibility: 12.1" high resolution visiual screen; Four different waves in one screen simultaneously
Greater Felexbility: Unique & practical ventilator menu for different respiration mode;
Greater Safety: Comprehensive monitoring & alarm system, effective data for safety and accuracy on operation;
Rotate screen freely, conviniently watch patient in any position;
FiO2: 21% to 100%,
Alarm recording function for tracking data.
Applications:
This machine can be used in respiratory management of after anesthestized operation, ambulance room, ICU, CCU, etc.
The patient type: Adult, Pediatric
Specifications:
|
Operating Modes
|
Volume Control Ventilation (VCV), Assisted/Controlled Pressure Control Ventilation (PCV),
Assisted/Controlled Pressure Support Ventilation (PSV),
SIMV(VCV)+PSV
SIMV(PCV)+PSV
Mandatory Minute Ventilation (MMV)
|
|
Parameter Selection according to the operating mode
|
FiO2: 21% to 100%
PEEP/CPAP: 0 to 40 cmH2O
Inspiratory Sensitivity:
Flow triggered: 0.5 to 20 L/min, OFF
Pressure triggered: -1 to -20 cmH2O, OFF
Tidal Volume: 20 to 2000 mL
Breath frequency: 1 to 100 bpm
I:E Ratio: 5.0 : 1 to 1 : 5.0
Inspiratory plateau: 0 to 50%
Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
SIGH: 1.0 to 2.0
Breath frequency(SIMV): 2 to 40bpm
Inspiratory time (SIMV): 0.1 to 12 S
Pressure Support Ventilation (PSV): 0 to 40 cmH2O
Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
Maximum Inspiratory time (PSV): 1.0 to 8.0 S
Pressure Control Ventilation(PCV): 0 to 40 cmH2O
Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
Backup Rate (PSV): 2 to 40 bpm
Object Tidal Volume(MMV): 20 to 2000 mL
Ventilation volume(MMV): 0.5 to 40.0 L/min
|
|
Alarms
|
High tidal volume
Low tidal volume
High minute ventilation
Low minute ventilation
High respiratory rate
Low respiratory rate
High peak pressure
Low peak pressure
High PEEP pressure
Low PEEP pressure
Low pressure of one gas (oxygen or air)
Apnea
AC power fail
Batterydisconnect
Low battery Circle block
|
|
Other features and controls
|
12.1 TFT
Pressure vs time curve
Flow vs time curve
Volume vs time curve
Pressure vs volume loops
Flow vs volume loops
Scale of graphics
Nebulizer
|
|
Power requirement
|
Main power: from 85 to 265VAC 47-63HZ
Automatic voltage switch
Internal battery: 12VDC; 7AH
Automatic recharge.
Estimated duration: more than 2 hours when completely charged.
The display shows an icon with the charge level.
|
|
Pneumatic requirement
|
Oxygen: pressure 2.8 to 6 bar ISO5359 connector
Air: pressure 2.8 to 6 bar ISO 5359 connector
|
|
Packing size
|
First in Carton, then packing in Synthetic case,
Size: 116 x 66 x 60
Gross weight: 98kg
|
Competitive Advantage:
Great Visibility: 12.1" high resolution visiual screen; Four different waves in one screen simultaneously
Greater Felexbility: Unique & practical ventilator menu for different respiration mode;
Greater Safety: Comprehensive monitoring & alarm system, effective data for safety and accuracy on operation;
Rotate screen freely, conveniently watch patient in any position;
FiO2: 21% to 100%,
Alarm recording function for tracking data.