Detailed Product Description
Pediatric and Adult Integrated Anesthesia Machines ARIES 2500 with Anesthesia Ventilator of VCV, PCV Respiratory Mode
Description:
Aluminium alloy frame has rail, can be upgraded with functions, eg, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.
With Volume & pressure ventilation modes,
Advanced electromagnetic valve ensures accurate tidal volume and compensation, use advanced differential pressure flow sensor to monitor tidal volume,
With 10.4” TFT color screen, waveform showed: P-t, F-t, V-t; Loops: F-v, V-p
Fresh gas outlet is in front of frame, the user can easily connect with Jackson –Rees circuit,
Working interfaces for adult and pediatric are separated; the doctor can choose interface according to patient type,
Classical CO2 circle absorber is with 2 canisters, low resistance, minimum gas leakage,
Optional: O2, N2O Yoke device. When main gas supply is failed, the backup gas supply can be automatically started.
Applications:
The Anesthesia Machine which is researched and produced by the Manufacturer Readeagle is a movable unit integrated with anesthesia and ventilation, which could be applied to closed anesthesia, semi-closed anesthesia, and semi-open anesthesia, and be applicable to Adult / Pediatric inhalation anesthesia, oxygen supply, resuscitation and respiratory management.
Specifications:
|
Patient type
|
Adult, pediatric
|
|
Respiration mode
|
IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO
|
|
Display:
|
10.4〞TFT color screen
|
|
Waveform
|
P-t, F-t, V-t, F-v, V-p
|
|
Tidal Volume
|
20~1600ml
|
|
Respiratory frequency
|
1~65bpm
|
|
I:E ratio
|
8:1~1:8
|
|
Inspiration pause
|
0~55%Ti
|
|
Inspiration Pressure
|
1~60cmH2O
|
|
Trigger Pressure
|
-20~20cmH2O
|
|
Monitoring parameters
|
O2 concentration,
MV,
Respiratory frequency,
Tidal volume,
Ppeak,
PEEP,
I:E ratio,
Pmean,
|
|
Alarm parameters
|
High pressure alarm,
Low pressure alarm,
O2 concentration alarm,
MV alarm,
O2 source failure alarm,
AC power failure alarm
|
|
Pressure alarm setting
|
High pressure alarm set 1~60cmH2O
Low pressure alarm set 0~20cmH2O
|
|
O2 concentration alarm setting
|
High: 21~99%
Low: 21~50%
|
|
MV alarm setting
|
MV high alarm set 10~99L/min
MV low alarm set 0~40L/min
|
|
Gas source pressure
|
O2: 0.25Mpa~0.65MPa
N2O: 0.25Mpa~0.65MPa
Air: 0.25Mpa~0.65MPa
|
|
O2 + N2O + Air flowmeter
|
Hypoxic guard system,keep oxygen concentration isn`t lower than 25%
|
|
Oxygen flush
|
25L/min~75L/min
|
|
Circle absorber
|
Safety valve pressure limit: 6Kpa
Good air tightness, high reliability and minor respiration impedance
With Manual/ Ventilation switch
|
|
Ventilator performance
|
Max. safety pressure : ≤6.0KPa
Compliance: ≤40m/KPa
Electrical Safety:
Meet requirements for Class I, type B equipment specified in EN60601-1
Medical Electrical equipment: Part one: General requirement for safety.
Noise: ≤ 65 dB(A)
|
|
Physical specification
|
Whole machine:
Length: 920mm
Width: 560mm
Height: 1490mm
Weight: 125Kg
Wheels: 100mm (diameter), 125mm (height), with brakes on the front two wheels
|
|
Environments
|
Temperature: Working: 18-36℃ Storage: -20-55℃
Comparative humidity: Working: 45%-75% Storage: ≤93%
Atmosphere: Working: 0.95~1.05 bar Storage: 500hpa~1060hpa,
Altitude:
Working: 500 to 800 mmHg (3565 to -440m)
Storage: 375 to 800 mmHg (5860 to -440m)
|
Competitive Advantage:
The Anesthesia Ventilator is one independent part, conveniently upgraded with new software,
Aluminium alloy frame has rail, can be upgraded with functions, eg, CO2 Monitor, Multi-parameter monitor, Anesthesia depth monitor, etc.
With Volume & pressure ventilation modes,
Advanced electromagnetic valve ensures accurate tidal volume and compensation, use advanced differential pressure flow sensor to monitor tidal volume,
With 10.4” TFT color screen, waveform showed: P-t, F-t, V-t; Loops: F-v, V-p
Fresh gas outlet is in front of frame, the user can easily connect with Jackson –Rees circuit,
Working interfaces for adult and pediatric are separated; the doctor can choose interface according to patient type,
Classical CO2 circle absorber is with 2 canisters, low resistance, minimum gas leakage,
Optional: O2, N2O Yoke device. When main gas supply is failed, the backup gas supply can be automatically started.